Sign In | Join Free | My chinacsw.com |
|
Brand Name : ANGES
Model Number : 20hp
Place of Origin : China
MOQ : 1
Payment Terms : T/T, L/C
Delivery Time : 15 days
Packaging Details : Plywood case
Cooling capacity : 60.2kw
Compressor type : Hermetic Scroll Compressor
Product name : Air Cooled Chiller
Evaporator : Plate Heat Exchanger , Tank with coil, Shell and tube
Water tank : 350L 304# Stainless Steel
Voltage : 380/415V 50/60HZ
Condition : Brandnew
After-sales service provided : Engineers available to service machinery overseas,Video technical support,Online support,Overseas third-party support available
Warranty : 12 Months
Refrigerant : R22/R404a/R407c/R134a
Laser chiller is used for laser cutting, laser welding, laser engraving, etc.
The composition of laser chiller is composed of compressor, condenser, throttling device, evaporator, water tank and water pump and other accessories.
Laser Chiller Specification
Model Item | AL-20W(D) | |
Nominal cooling capacity | Kcal/h | 51772 |
kw | 60.2 | |
Input power | kw | 20.76 |
Power supply | 3PH~380V/50HZ | |
Refrigerant | Type | R22 |
Type of control | Expansion valve | |
Compressor | Type | Hermetic scroll type |
Power (kw) | 16.2 | |
Condenser | Type | Finned copper tube+low noise outer rotor fan |
Power(kw) | 1.56 | |
Cooling air flow | 20000 | |
Evaporator | Type | Water tank with coil |
Chilled water flow | 10.38 | |
Tank volume(L) | 350 | |
Inlet/outlet pipe chiller(inch) | 2 | |
Water pump | Power(KW) | 3 |
Lift(m) | 28 | |
Safety protection | compressor over temperature, over-current protection, high and low pressure protection, over -temperature protection ,flow switch protection,phase sequence or missing phase protection,exhaust overheating protection | |
Net weight | kg | 835 |
Dimension | mm | 2000*1130*1820 |
Laser cutting machine water chiller failure possible causes:
The inlet end of the pipeline is blocked and air is inhaled;
Reverse connection of import and export pipeline;
Pump motor reversal or motor and pump shaft wear;
The oil used does not conform to the specifications or the level of the oil tank is lower than the lower limit;
The oil-water filter is blocked or the oil-water floating pressure ball is faulty;
Laser cutting machine water chiller fault solution:
Check and clean the oil circuit and tighten the pipeline;
Check that the import and export directions are correctly connected;
Updating the pump motor; Switch the red and white lines under the cumulative thermoelectric relay (51P);
As described in the instruction manual, select the compound oil and check whether the liquid level of the oil tank is normal;
Try to replace or clean the filter and try to replace the pressure float detection switch.
Featurers for air cooled laser chiller
![]() |
20hp Portable Air Cooled Water Chiller Modular Images |